ВНИМАНИЕ! График работы на майских праздниках: Офис в Москве: 9 мая ВЫХОДНОЙ!
Офис в СПБ: 1 мая, 9 мая - ВЫХОДНОЙ!
Mode Control Motor
Test
1. Connect the battery positive terminal to the ® terminal of the mode control motor and negative to the (2 terminal.
2. Using a jumper wire, short the ® terminal individually to the ®, ®, ®, © and ® terminals, in the order.
• The motor should run each time the short circuit is made.
NOTE: If the mode control motor does not run when shorting the first terminal, short that terminal again after shorting the other terminals.
The mode control motor is normal if it runs when shorting the first terminal again.
Replacement
1. Disconnect the mode control motor 8P connector and remove the female connector from the stay.
2. Remove the screws (3), mode control motor and flange collar.
3. Installation is the reverse of the removal procedure. After installation, make sure the mode control motor operates smoothly.