ВНИМАНИЕ! График работы на майских праздниках: Офис в Москве: 9 мая ВЫХОДНОЙ! Офис в СПБ: 1 мая, 9 мая - ВЫХОДНОЙ!

Blower Assembly

Replacement



NOTE: The blower motor, recirculation control motor, and resistor can be replaced without removing the blower assembly (see page 21-20).

1 . Disconnect the battery negative terminal.
2. Remove the glove box and glove box frame (section 20).
WITHOUT AIR CONDITIONER
3-a. Remove the clips from the heater duct.
Remove the tapping screws (2) and remove the heater duct.

WITH AIR CONDITIONER
3-b. Remove the evaporator (page 22-21).
4. Disconnect the connectors from the blower motor, resistor and recirculation control motor.

5. Remove the clamp from the recirculation control motor and release the wire harness from the clamp on the blower assembly.
Remove the bolts (2), nut and blower assembly.

6. Install the blower assembly in the reverse order of removal and make sure there is no air leakage.