Accumulator
Replacement
AWARNING Before removing the modulator-toaccumulator high pressure line, be sure to relieve the pressure fluid from the maintenance bleeder (page 19-81).
1. Loosen the flare nuts and remove the accumulator pipe.
2. Remove the three mounting bolts and the accumulator from the modulator unit.
3. Install a new accumulator in the reverse order of removal.
4. Bleed the air from the high-pressure line (page 19-86).
. Disposal -
AWARNING The accumulator contains high pressure nitrogen gas. Do not puncture, expose to the flame, or attempt to disassemble the accumulator or it may explode and severe personal injury may result.
1. Secure the accumulator in a vise so that the relief plug points straight up.
2. Slowly turn the plug 3-1 /2 turns and then wait 3 minutes for all pressure to escape.