No. | Terminal | Test condition | Test: desired result | Possible cause (if result is not obtained) |
1 | E | Under all conditions. | Check for continuity to ground: there should be continuity. | • Poor ground (G201, G401). • An open in the BLK wire. |
2 | B | Ignition switch ON. | Check for voltage to ground: there should be battery voltage. | • Blow No. 15 (10 A) fuse. • An open in the YEL or GRN/WHT wire. • Faulty hazard switch. |
Hazard switch ON. | Check for voltage to ground: there should be battery voltage. | • Blown No. 43 (10 A) fuse. • An open in the WHT/GRN or GRN/WHT wire. • Faulty hazard switch. | ||
3 | L | Hazard switch ON and connect the B terminal to the L ter- minal. | Hazard lights should come on. | • Poor ground (G201, G301, G401, G553, G554, G771), • Faulty hazard switch. • An open in the GRN/RED, GRN/YEL, GRN/BLU or BLK wire. |
Ignition switch ON and turn signal switch in R or L and connect the B terminal to the L terminal. | R or L turn signal lights should come on. | • Faulty turn signal switch. |